HKV3000 and HKV4000 High Temperature Baths with Integrated Digital Timing

HKV3000 and HKV4000 High Temperature Baths with Integrated Digital Timing

MARCA: KOEHLER

• Microprocessor temperature control between ambient and 232°C (450°F) • Integrated digital timing for convenient measurement of sample efflux times

Consulte
• HKV4000 model permits entry of viscometer constants for automatic calculation and display in viscosity units or seconds
• Dual digital displays show setpoint and actual bath temperature
• Selectable temperature scale - Fahrenheit or Celsius
• Integrated redundant overtemperature and low liquid level cut-off circuitry
• Conforms to ASTM D445, D2170 and related specifications

High temperature baths with advanced temperature control circuitry and integrated timing features for convenient, accurate glass capillary viscometry determinations. Microprocessor PID circuitry assures precise, reliable temperature control within ASTM specified tolerances throughout the operating range of the bath. Simple push-button controls and dual digital displays permit easy setting and monitoring of bath temperature. Two place calibration offset capability is provided. Baths accommodate seven glass capillary viscometers of various types - see pages 10-13 for complete selection of viscometers and holders. Viewing the viscometers is made easy by glare-free fluorescent illumination inside the bath and a baffle that provides a background for easy viewing. Temperature control uniformity is assured by means of motorized stirrer which provides complete circulation without turbulence. Connection of the built-in cooling coil to tap water or a recirculating water chiller facilitates temperature control at ambient or below ambient temperatures.

Specifications
Conforms to the specifications of: ASTM D445, D2170, D6074, D6158; IP 71, 319; ISO 3104; DIN 51550; FTM 791-305; NF T 60-100
Temperature Control
Range: ambient to 232°C (450°F); sub-ambient to 10°C with external cooling
Display: 0.1°C/0.1°F resolution, calibrate to 0.01°C/0.01°F
Control accuracy and uniformity: Exceeds ASTM requirements throughout the operating range
Integrated timing
HKV3000: Seven individual start/stop timers with displays to 0.01s, accurate to within 0.01%
HKV4000: Integrated LCD microcomputer with start/stop buttons and retention of viscometer tube constants, automatic calculation and display in viscosity units or seconds to 0.1s, within 0.01% accuracy.
Communication: RS232 port included with HKV4000 (optional for HKV3000)
Viscometer ports: Seven round 2" (51mm) ports
Bath Medium: water or suitable heat transfer fluid